Automatic Polarimeter / Saccharimeter SAC-i 589/882


PHÂN CỰC KẾ TỰ ĐỘNG ĐO ĐƯỢC CẢ MẪU ĐƯỜNG NGUYÊN CHẤT ATAGO

High Performance Sugar Analysis, Now Easier Than Ever.


It has become common that dark color - raw sugar samples are measured at 882nm without decolorization treatment.
SAC-i 589/882 can measure samples at both 589nm and 882nm by changing the optical units.
Specifications
ModelSAC-i 589/882
Cat.No.5952
ScaleAngle of Rotation,
International Sugar Scale (without temperature compensation),
International Sugar Scale (with Automatic Temperature Compensation)
Measurement ReadingsAngle of Rotation
International Sugar Scale (without temperature compensation)
International Sugar Scale (with Automatic Temperature Compensation)
Specific Rotation
Concentration
Purity
User scale
Angle of Rotation (Temperature Compensation of Quartz Plate)
Temperature (°C / °F)
Measurement RangeAngle of Rotation:-89.9999 to +90.0000° and -360.0000 to +360.0000°
International Sugar Scale : -259.0000 to +259.0000°Z
ResolutionAngle of Rotation : 0.0001°
International Sugar Scale : 0.0001°Z
Measurement Accuracy589nm: 
Angle of Rotation :
±0.002°(-5.0000~+5.0000°)
±0.005°(-45.014~-5.0001°,+5.0001~+45.0140°)
International Sugar Scale :±0.015°Z (-130.0000 to +130.0000°Z)
Other ranges Angle of Rotation :±0.010°
International Sugar Scale :±0.03°Z

882nm: 
Angle of Rotation :
±0.005° (-19.3000 to +19.3000°)
International Sugar Scale :±0.015°Z (-130.0000 to +130.0000°Z)
Other ranges Angle of Rotation :±0.010°
International Sugar Scale :±0.07°Z
Temperature compensation range10 to 40℃
Ambient TemperatureUse the instrument where the temperature is between 10 to 40°C
Display Panel7.5 inch color LCD (touch screen)
Temperature display accuracy±0.2 °C
Light sourceLED:
589nm interference filter,
882nm interference filter
PrismGlan-Taylor Prism
Measurement Wavelength589nm (equivalent to the sodium-D line spectrum)
882nm(infrared nearby)
Power SupplyAC100 to 240V, 50/60Hz
Included AccessoriesSoftware, PolariSoft
Observation tube includedObservation tubes (100mm(5mL),200mm(10mL))
Dimensions & Weight60×36.5×21cm, 20.0kg
Power consumption140VA
Output terminalsDigital Printer DP-63 or
DP-AD (sold separately), 
Output method : RS-232C (9 pin D-Sub male connector)
USB flash drive and PC - USB
Options
· Observation tube 50mm OT-50(I) (SUS) 2.5mL : RE-72080
· Observation tube 100mm OT-100(I) (SUS) 5mL : RE-72078
· Observation tube 200mm OT-200(I) (SUS) 10mL : RE-72079
· Jacketed flow tube with funnel 100mm : RE-72113
· Jacketed flow tube with funnel 200mm : RE-72114
· Unjacketed flow tube with funnel 100mm : RE-72037
· Unjacketed flow tube with funnel 200mm : RE-72038
· Unjacketed small volume observationtube 10mm long : RE-72042
· Jacketed flow tube 50mm(With water jacket) : RE-72110
· Jacketed flow tube 100mm (With water jacket) : RE-72111
· Jacketed flow tube 200mm(With water jacket) : RE-72112
· Unjacketed Flow Tube (Glass) 50mm/4.5mL : RE-72051
· Unjacketed Flow Tube (Glass) 100mm/9mL : RE-72052